======================================================================== STATIC FIRE REPORT ======================================================================== Input file: TMS\Data\2026\5_28\TMS_9.TXT Sampling rate: 320 sps ------------------------------------------------------------------------ THRUST METRICS ------------------------------------------------------------------------ Ignition delay: 3246.9 ms Peak thrust: 174.19 N Total impulse: 366.33 N s Average thrust: 129.96 N Burn duration: 2818.7 ms ------------------------------------------------------------------------ PRESSURE METRICS ------------------------------------------------------------------------ Peak pressure: 42.496 bar at 4.228 s ------------------------------------------------------------------------ CALIBRATION ------------------------------------------------------------------------ Loadcell calibration slope: -0.039100 kg/ADC Loadcell calibration intercept: -193.0049 kg Loadcell calibration R^2: 0.999948 Pressure conversion: y = 0.0027x -0.11 ------------------------------------------------------------------------ DATA PROCESSING ------------------------------------------------------------------------ Loadcell offset is measured from the pre-ignition raw-force window, then subtracted from raw force to create corrected force. Pressure offset is measured from the initial filtered-pressure window, then subtracted from both raw pressure and filtered pressure to create gauge pressure. Loadcell baseline offset: -2.972460 N Pressure baseline offset: -0.017733 bar Loadcell baseline window: 0.000000 to 1.625000 s (520 samples, pre-ignition raw force) Pressure baseline window: first 0.500 s (160 samples, filtered pressure) Loadcell low-pass: applied to corrected force at 20.0 Hz, order 2 Pressure low-pass: applied to raw pressure at 5.0 Hz, order 4 Threshold: 5.23 N (3% of peak filtered force) ========================================================================