======================================================================== STATIC FIRE REPORT ======================================================================== Input file: TMS/Data/2026/7_23/7_23 data.TXT Sampling rate: 320 sps ------------------------------------------------------------------------ DATA QUALITY ------------------------------------------------------------------------ Thrust status: event_detected Pressure status: usable Time axis assumes uniform 320 Hz sampling; no per-sample timestamps are logged. Ignition delay is time from recording start, not an independently logged fire command. Calibration is inherited from the existing pipeline; no same-day calibration was supplied. ------------------------------------------------------------------------ THRUST METRICS ------------------------------------------------------------------------ Ignition delay: 3803.1 ms Peak thrust: 143.98 N Total impulse: 319.91 N s Average thrust: 117.40 N Burn duration: 2725.0 ms ------------------------------------------------------------------------ PRESSURE METRICS ------------------------------------------------------------------------ Peak pressure: 17.061 bar at 4.416 s ------------------------------------------------------------------------ CALIBRATION ------------------------------------------------------------------------ Loadcell calibration slope: -0.039100 kg/ADC Loadcell calibration intercept: -193.0049 kg Loadcell calibration R^2: 0.999948 Pressure conversion: y = 0.0027x -0.11 ------------------------------------------------------------------------ DATA PROCESSING ------------------------------------------------------------------------ Drift correction: Constant baseline offset Thrust metrics are calculated from filtered corrected force. Pressure metrics are calculated from filtered gauge pressure. Loadcell threshold (fixed absolute): 5.00 N Loadcell filter: Butterworth low-pass 20.0 Hz, order 2 Pressure filter: Butterworth low-pass 5.0 Hz, order 4 Pressure baseline offset: 9.380857 bar Pressure baseline window: first 0.500 s (up to 160 samples, filtered pressure) Loadcell offset is measured from pre-event raw force and subtracted before filtering. Pressure validity is checked before any offset subtraction; invalid channels remain unavailable. Loadcell baseline offset: -21.083218 N Loadcell baseline window end: 1.900000 s (608 samples) Ignition start time: 3.803125 s ========================================================================