======================================================================== STATIC FIRE REPORT - BURN SPLIT ACROSS TWO RECORDINGS ======================================================================== Input files: TMS/Data/2026/11_23/TMS_2.TXT + TMS/Data/2026/11_23/TMS_3.TXT Sampling rate: 320 sps ------------------------------------------------------------------------ DATA QUALITY ------------------------------------------------------------------------ Thrust status: measured with a fitted unsampled interval (historical_template_median) Pressure status: unverified_does_not_track_thrust Time axis assumes uniform 320 Hz sampling; no per-sample timestamps are logged. Second file aligned by sampling-start headers: offset 15.519536 s. Unsampled interval: 14.737500 to 15.519536 s (0.782036 s). Ignition delay is time from the first recording's start, not an independently logged fire command. Calibration is inherited from the existing pipeline; no same-day calibration was supplied. ------------------------------------------------------------------------ THRUST METRICS ------------------------------------------------------------------------ Ignition delay: 12771.9 ms Peak thrust (measured): 149.17 N at 14.512500 s Total impulse (estimated): 361.18 N s (range 356.88-363.55) Measured: 250.92 N s (first file 210.70, second file 40.22) Fitted interval: 110.26 N s (range 105.96-112.63) Average thrust (estimated): 104.66 N Burn duration: 3450.8 ms (12.771875 to 16.222661 s) ------------------------------------------------------------------------ UNSAMPLED INTERVAL FIT ------------------------------------------------------------------------ Templates: earlier firings fitted to the last 1.0 s before the gap and the measured decay; pinned to both edges. Edge force: 147.83 N / 116.44 N Accepted (RMS <= 6.0 N): 4_2 (5.63 N), 4_8 (3.48 N), 5_28 (5.63 N), 10_13 (5.70 N) Rejected: 7_16 (9.74 N), 7_23 (6.96 N), 7_24 (16.85 N) Knee-fit cross-check total: 360.99 N s; straight-bridge gap impulse: 103.34 N s Measured impulse alone is a lower bound for non-negative thrust. ------------------------------------------------------------------------ PRESSURE METRICS ------------------------------------------------------------------------ Drift-corrected peak: 10.169 bar at 13.353125 s (thrust 95.3 N) Correlation with thrust during burn: r = 0.34 (minimum for use 0.50) Thrust-free residual: 0.535 bar RMS After drift removal the in-burn signal peaks before thrust reaches its plateau and then falls while thrust is still rising; chamber pressure cannot do that. Values are retained for diagnosis, not as chamber pressure. ------------------------------------------------------------------------ CALIBRATION ------------------------------------------------------------------------ Loadcell calibration slope: -0.039100 kg/ADC Loadcell calibration intercept: -193.0049 kg Loadcell calibration R^2: 0.999948 Pressure conversion: y = 0.0027x -0.11 ------------------------------------------------------------------------ DATA PROCESSING ------------------------------------------------------------------------ Loadcell threshold (fixed absolute): 5.00 N Loadcell baseline offset: -60.100961 N (first file, up to 6.387500 s), applied to both files Return to baseline in second file: -0.558 +/- 0.180 N Loadcell filter: Butterworth low-pass 20.0 Hz, order 2; each file separately Pressure: 0.10 s running median on raw ADC, inherited conversion, then a PCHIP baseline through 0.5 s medians of thrust-free periods (zero gauge pressure assumed there) is subtracted. filtered_force_N is measured only (nan in the gap); analysis_force_N includes the fitted interval. ========================================================================